Shear Power. Pure Canaloplasty.

Shear Clear™ Technology is iTrack™ Advance's approach to viscoelastic delivery.

Ever wonder what would happen if viscoelastic during canaloplasty wasn’t so… viscous?

Shear Clear™ Technology transforms cohesive viscoelastic into a low-viscosity fluid during canaloplasty, enabling it to circulate more freely and penetrate deeper into the trabecular outflow pathway.
Learn more about Shear Clear™
White Arrow Pointing Right

The Science Behind the Power

What is Shear Thinning?
Viscoelastic shearing — or shear thinning — is how viscoelastic temporarily changes viscosity under the high shear stresses generated by Shear Clear™ Technology.
1
At rest, cohesive viscoelastic behaves like a high-viscosity gel.
2
Shear forces in iTrack™ Advance temporarily transform the viscoelastic into a fluid-like state.
3
Shear forces are released, returning the viscoelastic to its original gel-like state.
shearclear logo gradient
What is Shear Clear™ Technology?
Viscoelastic shearing — or shear thinning — is how viscoelastic temporarily changes viscosity under the high shear stresses generated by Shear Clear™ Technology.
The patented internal micro-architecture of the microcatheter — including a woven nitinol guidewire — generates controlled turbulence that maximises shear stress.
Viscoinjector icon
The ViscoInjector™ connects via a 24-inch infusion line, through which viscoelastic is pushed under high pressure to maximise shear stress.
Explore iTrack™ Advance
White Arrow Pointing Right

How Shear Clear™ Works

Shear thinning infographic
Viscosity Drop
Optical rheology testing has shown iTrack™ Advance can generate a high shear rate, achieving a 190-fold reduction in viscosity.*
Change in Viscosity of Healon Pro Over Time During Priming, Delivery and Post-Delivery with the iTrack™ Advance*
shear thinning data visualisation
*In-house bench testing data using a proprietary optical rheology test apparatus to assess the change in viscosity over time during viscoelastic delivery with the iTrack™ Advance. Bench testing data may not be indicative of clinical outcomes. Data available on reasonable request.

Shear Clear™ Technology at a Glance

Once thinned with shear force, viscoelastic can circulate more freely within Schlemm's canal.*
Viscoinjector icon
Visible intraoperative blanching of the limbus vessels and episcleral venous system may illustrate this effect.*
The thinned viscoelastic may penetrate deeper into the trabecular outflow pathway, including collector channels.*
shearclear logo gradient
As post-delivery shear forces dissipate, the viscoelastic regains viscosity.
*Clinical effects depend on anatomy and surgical technique. Results may vary.
Learn about canaloplasty
White Arrow Pointing Right

Contact us

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
*In-house bench testing data using a proprietary optical rheology test apparatus to assess the change in viscosity over time during viscoelastic delivery with the iTrack™ Advance. Bench testing data may not be indicative of clinical outcomes. Clinical effects depend on anatomy and surgical technique. Results may vary.