Nova Eye Medical
Itrack Advance White Logo

Advancing canaloplasty to the next level.

See video demo

Canaloplasty, with control built in

iTrack™ Advance brings canaloplasty to both glaucoma and cataract surgeons with a repeatable and flexible workflow. Surgeons navigate Schlemm’s canal using an illuminated microcatheter tip for transscleral visualization, then deliver pressurized viscoelastic—without tearing tissue, and without leaving implants behind.


Featuring Shear Clear™ Technology, iTrack™ Advance creates shear forces that temporarily reduce viscoelastic viscosity during delivery, supporting distribution through Schlemm’s canal and into collector channels during a full 360° pass.

360º

Catheterization plus pressurized viscodilation across the full 360° of the conventional outflow pathway, supporting a comprehensive canaloplasty approach.

In-house manufacturing

Engineered and precision-crafted in our state-of-the-art facilities

Clinically proven iTrack™ technology

Built on the established iTrack™ platform, with clinical evidence supporting long-term effectiveness and real-world adoption. (1), (2)

Kerr, N., Lubeck, D., Barton, K., Aref, A. A., Cheng, J., Spaulding, J., Shoham-Hazon, N., Thomsen, S., Patel, S., Harasymowycz, P., Singh, H., Mercieca, K., & Ahmed, I. I. K. (2026). A Prospective, Real-World, Multicenter Study to Support the Role of Ab-Interno Canaloplasty in Glaucoma Management. American journal of ophthalmology, 284, 235–246.
Gallardo M. J. (2022). 36-Month Effectiveness of Ab-Interno Canaloplasty Standalone versus Combined with Cataract Surgery for the Treatment of Open-Angle Glaucoma. Ophthalmology. Glaucoma, 5(5), 476–482.

the iTrack™ Advance’s all-in-one handheld injector

Device
Cannula
Spatulated tip design for ease of access into Schlemm's canal.
Nozzle
Nozzle can be rotated 360° to precisely position the cannula.
Actuator
Smooth gliding mechanism for precise advancement and retraction of microcatheter during canal intubation and withdrawal.
ViscoInjector™ delivery control
Assistant-operated mechanism that supports consistent, pressurized delivery of viscoelastic while the surgeon focuses on microcatheter control.
Shearclear gradient logo
Shear Clear™ pressurized delivery
Our proprietary internal microcatheter architecture combines with the pressurized delivery mechanism of the ViscoInjector™ to create shear forces that temporarily reduce viscoelastic viscosity during delivery, supporting distribution through Schlemm’s canal and into collector channels.
Shearclear gradient logo
Up close picture of the iTrack Device's tip
Illuminated microcatheter tip
Provides transscleral visualization to help confirm microcatheter position during 360° navigation
Optical Fiber
Optical Fiber connects to the portable iLumin™ light source.
Guidewire Mechanism
Internal guidewire to push through adhesions and to move through tight areas or structures of the canal.
Infusion Pathway
Infusion pathway that connects to ViscoInjector™ OVD delivery system.

Canaloplasty insights from the field

Surgeon perspectives on canaloplasty with iTrack™ Advance, focused on physiological outflow restoration and procedural control
Quote symbol in white

The best part about the iTrack™Advance is that it’s a
simple, straightforward procedure where I can catheterize
the entire canal from one site, in one direction, with a lit
microcatheter that enables me to see exactly where I am.

J. Morgan Micheletti, MD, FACS (USA)

Dr Micheletti BW photo
Learn more
White Arrow Pointing Right

Canaloplasty insights from the field

Surgeon perspectives on canaloplasty with iTrack™ Advance, focused on physiological outflow restoration and procedural control
Quote symbol in white

I love the iTrack™Advance for many reasons. I like that the handpiece has a single slider, so you can push from one end to the other and deploy the entire catheter with one push of one finger. It's just one smooth push. I also love the illuminated tip.

Mary Qiu, MD (USA)

Mary Qiu BW photo
Learn more
White Arrow Pointing Right

Canaloplasty insights from the field

Surgeon perspectives on canaloplasty with iTrack™ Advance, focused on physiological outflow restoration and procedural control
Quote symbol in white

Not only does iTrack™ Advance break the herniations in the canal, but it also viscodilates. So, it's flushing out the entire
distal channel and also opening up the trabecular meshwork.

I. Paul Singh, MD (USA)

Learn more
White Arrow Pointing Right

Canaloplasty insights from the field

Surgeon perspectives on canaloplasty with iTrack™ Advance, focused on physiological outflow restoration and procedural control
Quote symbol in white

The illuminated tip is operating with a safety net. You always know the location of your microcatheter at any given time—and that is just better than having to guess where it is in the eye.

Rachel Gartell-Simpson, MD (USA)

Learn more
White Arrow Pointing Right

Designed for canaloplasty,
refined for the OR.

iTrack™ Advance brings together illumination, pressurized viscoelastic delivery and surgeon-driven ergonomics to support a canaloplasty workflow built for control and repeatability while working with the eye’s natural outflow physiology.

Ultimately, it’s canaloplasty
without compromise.

360 gradient icon
360°
Transverses 360° of the conventional pathway in a single intubation
iTrack™ Advance's ultra-small outer shaft is design to navigate Schlemm's canal while protecting the system's internal components.
Pressure Gradient Icon
Illuminated tip
Visual confirmation during navigation
iLumin™ illuminated microcatheter tip supports real-time microcatheter location feedback during navigation.
refresh gradient icon
2:1 gearing
One continuous forward actuator movement transverses the full circumference of the canal
Designed to reduce stop-start hand motions that can destabilize technique during a full 360° pass.
Shearclear gradient logo
ILLUMINATED CANALOPLASTY
Internal microarchitecture in the microcatheter, teamed with the Viscoinjector™, is designed to generate shear forces that temporarily reduce viscosity during delivery.*

*In-house bench testing data using a proprietary optical rheology test apparatus to assess the change in viscosity over time during viscoelastic delivery with the iTrack™ Advance. Bench testing data may not be indicative of clinical outcomes. Clinical effects depend on anatomy and surgical technique. Results may vary.

Using the iLumin™ illuminated microcatheter tip in canaloplasty

iTrack™ Advance Training Video: Healon and the ViscoInjector

What the experts say about canaloplasty with iTrack™ Advance

Nova Eye Medical, equips your surgeons with the best equipment for a non-destructive, long-term, patient care focused solution.

Quote symbol in white
The new iTrack™ Advance makes it so easy to get into Schlemm's canal with limited damage to the tissue.
Karsten Klabe
MD
Quote symbol in white
The new iTrack™ Advance makes it so easy to get into Schlemm's canal with limited damage to the tissue.
William Wiley
Arrow pointing Left white icon
White Arrow Pointing Right
Viscosity Drop

Pure Canaloplasty with Shear Clear™ Technology 

Shear thinning with Shear Clear™ Technology transforms cohesive viscoelastic into a low-viscosity fluid during canaloplasty. Thinned viscoelastic circulates more freely, assisting in penetration of the conventional outflow pathway during viscodilation.
Viscosity Drop
Learn more about Shear Clear™
White Arrow Pointing Right

Why iTrack Advance™?

This is some text inside of a div block.
iTrack Advance™ Logo Black
Treat resistance across the full 360° conventional outflow pathway
Gradient Check Icon
Illuminated catheter tip supports transscleral visualization during navigation
Gradient Check Icon
Shear Clear™ Technology generates shear forces that influence viscoelastic delivery behavior
Gradient Check Icon
Handpiece mechanics designed for stable, continuous advancement
Gradient Check Icon
High volume, pressurized viscoelastic delivery
Gradient Check Icon
Learn more
White Arrow Pointing Right

Contact us

Not all products are available in all regions or countries. Please contact your Nova Eye representative for more information.
Surgeons in the Operating room using itrack devices
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Contact us

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
*In-house bench testing data using a proprietary optical rheology test apparatus to assess the change in viscosity over time during viscoelastic delivery with the iTrack™ Advance. Bench testing data may not be indicative of clinical outcomes. Clinical effects depend on anatomy and surgical technique. Results may vary.

Disclaimer

Get the latest Nova Eye Medical news alerts, straight to your inbox

Thank you for subscribing to our newsletter!
Oops! Something went wrong while submitting the form. Please try again.

Get the latest Nova Eye Medical news alerts, straight to your inbox

Thank you for subscribing to our newsletter!
Oops! Something went wrong while submitting the form. Please try again.